Chapter 10 Summary of Parameter Settings|C200 Series
Parameter
07-22
Energy-saving Gain
Auto Voltage
07-23
Regulation(AVR) Function
Filter Time of Torque
07-24
Command (V/F and SVC
control mode)
Filter Time of Slip
07-25
Compensation (V/F and
SVC control mode)
Torque Compensation
07-26
Gain (V/F and SVC control
mode)
Slip Compensation Gain
07-27
(V/F and SVC control
mode)
07-28
Reserved
07-29
Slip Deviation Level
Detection Time of Slip
07-30
Deviation
07-31
Over Slip Treatment
07-32
Motor Hunting Gain
Auto Reset Time for
07-33
Restart after Fault
Call 1(800)985-6929 for Sales
deltaacdrives.com
Explanation
10~1000%
0: Enable AVR
1: Disable AVR
2: Disable AVR during deceleration
0.001~10.000 sec
0.001~10.000 sec
0~10
0.00~10.00
0.0~100.0%
0: No detection
0.0~10.0 sec
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning
0~10000
0.0~6000.0 sec
deltaacdrives.com
Settings
10-24
sales@deltaacdrives.com
Factory
Setting
100
0
0.020
0.100
0
0.00
0
1.0
0
1000
60.0
sales@deltaacdrives.com