Display the Frequency Command Executed by External Terminal
Settings Read only
When the source of frequency command comes from the external terminal, if Lv or Fault occurs at
this time, the frequency command of the external terminal will be saved in this parameter.
Digital Output Gain(DFM 2)
Settings 0~106
It is used to set the signal for the digital output terminals (DFM 2-DCM) and digital frequency output
(pulse X work period=50%). Output pulse per second = output frequency X Pr.02-55 ≤ 33kHz.
When Pr02-55=0, the external terminal (DFM2) will be multi-function output. Pr02-17 sets up the
function of DFM1's output.
When Pr02-55≥1, the external terminal (DFM2) will be digital frequency output. Output frequency =
H*Gain.
Call 1(800)985-6929 for Sales
deltaacdrives.com
Chapter 11 Description of Parameter Settings|C200 Series
0=NOT used by PLC
1=Used by PLC
2 2
2
2
2
Weights
4
3
2
1
0
Bit
0
0
1
0
1
11-43
deltaacdrives.com
Display value
Relay 1
3=2+1
Relay 2
=1x2 +1x2
1
0
Reserved
=bit 1x2 +bit 0x2
1
DFM1
DFM2
Factory Setting: Read only
Factory Setting: 1