Delta C200 Series User Manual page 127

Intelligent vector control drive
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
OFF: contact is open)
Settings
0
No Function
Multi-step speed command
1
1/multi-step position command
1
Multi-step speed command 2/
2
multi-step position command 2
Multi-step speed command 3/
3
multi-step position command 3
Multi-step speed command 4/
4
multi-step position command 4
5
Reset
6
JOG Command
Acceleration/deceleration
7
Speed Inhibit
The 1
8
deceleration time selection
The 3
9
deceleration time selection
10
EF Input (EF: External fault)
External B.B. Input (Base
11
Block)
12
Output Stop
Call 1(800)985-6929 for Sales
Functions
st
nd
, 2
acceleration or
rd
th
, 4
acceleration or
deltaacdrives.com
Chapter 11 Description of Parameter Settings|C200 Series
15 step speeds could be conducted through the digital status of the 4
terminals, and 16 in total if the master speed is included. (Refer to
Parameter set 4)
After the error of the drive is eliminated, use this terminal to reset the
drive.
Before executing this function, it needs to wait for the drive stop
completely. During running, it can change the operation direction and
STOP key on the keypad is valid. Once the external terminal
receives OFF command, the motor will stop by the JOG deceleration
time. Refer to Pr.01-20~01-22 for details.
0 1- 22
JO G fr eq ue ncy
0 1- 07
Min. o utp ut freq ue ncy
o f moto r 1
JO G a ccel. time
0 1-20
MIx-G ND
When this function is enabled, acceleration and deceleration is
stopped. After this function is disabled, the AC motor drive starts to
accel./decel. from the inhibit point.
Fr eq ue ncy
S etti ng
A ccel . in hi bi t
fr eq uency
a re a
A ccel. in hi bi t
a rea
Actua l o pe ra tion fr eq ue ncy
O N
MIx- GND
O pe ra tio n
co mman d
The acceleration/deceleration time of the drive could be selected from
this function or the digital status of the terminals; there are 4
acceleration/deceleration speeds in total for selection.
External fault input terminal. It will decelerate by Pr.07-20 setting (it
will have fault record when external fault occurs)
When this contact is ON, output of the drive will be cut off immediately,
and the motor will be free run and display B.B. signal.
Pr.07-08 for details.
If this contact is ON, output of the drive will be cut off immediately, and
the motor will then be free run. And once it is turned to OFF, the drive
will accelerate to the setting frequency.
11-28
deltaacdrives.com
sales@deltaacdrives.com
Descriptions
JO G d ece l. ti me
01 -2 1
O FF
O N
De cel . in hibit
a re a
A ctua l o pe ra tio n
fr eq uency
De cel . in hi bi t
a re a
O N
O N
O N
sales@deltaacdrives.com
Time
O N
O FF
Refer to