Delta C200 Series User Manual page 330

Intelligent vector control drive
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
API
MOV
12
D
Bit Devices
X
Y
M
S
D
Operand: None
E xplanation
Example
Call 1(800)985-6929 for Sales
deltaacdrives.com
S
D
P
Word Devices
K
H KnX KnY KnM T
1.
S: Source of data
2.
When this instruction is executed, the content of S will be moved directly
to D. When this instruction is not executed, the content of D remains
unchanged.
1.
When X0 = Off, the content in D10 will remain unchanged. If X0 = On, the
value K10 will be moved to D10 data register.
2.
When X1 = Off, the content in D10 will remain unchanged. If X1 = On, the
present value T0 will be moved to D10 data register.
deltaacdrives.com
Chapter 14 PLC Function |C200 Series
Moving the data
16-bit command (5 STEPS)
MOV
C
D
32-bit command (9 STEPS)
Flag signal: None
D: Destination of data
X0
MOV
X1
MOV
14-45
sales@deltaacdrives.com
MOVP
K10
D0
T0
D10
sales@deltaacdrives.com