Reserved
Electrical Gear at Load Side A1
Electrical Gear at Motor Side B1
Electrical Gear at Load Side A2
Electrical Gear at Motor Side B2
Settings 1~65535
Parameters 10-04 to 10-07 can be used with the multi-function input terminal (set to 48) to switch
to Pr.10-04~10-05 or Pr.10-06~10-07 as shown as follows
Treatment for Encoder Feedback Fault
Settings 0: Warn and keep operating
Detection Time of Encoder Feedback Fault
Settings 0.0~10.0 sec
When encoder loss, encoder signal error, pulse signal setting error or signal error, if time exceeds
the detection time for encoder feedback fault (Pr.10-09), the encoder signal error will occur. Refer
to the Pr.10-08 for encoder feedback fault treatment.
Encoder Stall Level
Settings 0~120%
This parameter determines the maximum encoder feedback signal allowed before a fault occurs.
Call 1(800)985-6929 for Sales
deltaacdrives.com
5: Single-phase input
A
load
encoder is us ed
at load side
1: Warn and RAMP to stop
2: Warn and COAST to stop
0: No function
0: No function
11-133
deltaacdrives.com
Chapter 11 Description of Parameter Settings|C200 Series
PG
car d
Gear
Gear
B1 or B2
A1 or A2
gear ratio
ON = A2: B2
MI=48
OF F=A 1:B 1
sales@deltaacdrives.com
Factory Setting: 100
D riv er
Motor
Factory Setting: 2
Factory Setting: 1.0
Factory Setting: 115
sales@deltaacdrives.com