Delta C200 Series User Manual page 129

Intelligent vector control drive
Table of Contents

Advertisement

Call 1(800)985-6929 for Sales
Settings
27
ASR1/ASR2 selection
28
Emergency stop (EF1)
Signal confirmation for
29
Y-connection
Signal confirmation for
30
Δ-connection
31
High torque bias
32
Middle torque bias
33
Low torque bias
34~37 Reserved
Disable EEPROM write
38
function
39
Torque command direction
40
Force coast to stop
41
HAND switch
42
AUTO switch
43~47 Reserved
48
Mechanical gear ratio switch
Call 1(800)985-6929 for Sales
deltaacdrives.com
Functions
RU N/STOP
command
Multi- func ti on i np ut
ter minal is set to 26
(to rque/speed
mode sw itch )
03 -0 0~02= 1
(AVI/AUI/ACI i s
fr eq uency command)
03 -0 0~02= 2
(AVI/AUI/ACI i s
tor que command)
When the contact is ON: speed will be adjusted by ASR 2 setting.
OFF: speed will be adjusted by ASR 1 setting. Refer to Pr.11-02 for
details.
When the contact is ON, the drive will execute emergency stop and
display EF1 on the keypad. The motor won't run and be in the free run
until the fault is cleared after pressing RESET" (EF: External Fault)
When is the contact is ON, the drive will operate by 1st V/f.
When the contact is ON, the drive will operate by 2nd V/f.
Refer to Pr.11-30~11-32 for details.
When this contact is ON, write to EEPROM is disabled.
For torque control (Pr.00-10=2), when torque command is AVI or ACI,
the contact is ON and it is negative torque.
When this contact is ON during the operation, the drive will free run to
stop.
1. When MI is switched to off status, it executes a STOP command. ,
2. Using keypad KPC-CC01 to switch between HAND/AUTO, the
3. On the digital keypad KPC-CC01, it will display current drive
When this contact is ON, the mechanical gear ratio switch will be the
deltaacdrives.com
Chapter 11 Description of Parameter Settings|C200 Series
Descriptions
ON
OFF
speed limit
sp eed
command
tor que
torque
limit
command
sp eed
contro l
tor que
co ntrol
mode
control
Sw itch timing for t orq ue/speed contr ol
(00-10=0/4 , mu lt i-fu nct ion inpu t t erminal is set to 2 6)
V oltag e
Fr eq ue ncy
S etti ng
fr eq ue ncy
MI - GND
x
Re set
O pe ra tio n
co mman d
If MI is switched to off during operation, the drive will also stop.
drive will stop first then switch to the HAND or AUTO status.
status (HAND/OFF/AUTO).
OFF
AUTO
HAND
OFF
11-30
sales@deltaacdrives.com
RU N
OFF
ON
sp eed
speed limit
command
tor que
limit
tor que
command
sp eed
tor que
co ntrol
control
OFF
O N
ON
O FF
O N
Bit 1
Bit 0
0
0
0
1
1
0
1
1
sales@deltaacdrives.com
STOP
sp eed
co ntrol
(decel. t o stop )
Ti me
ON

Advertisement

Table of Contents
loading

Table of Contents