01 Basic Parameters
Parameter
01-00
Max. Operation Frequency
01-01
Output Frequency of Motor 1
01-02
Output Voltage of Motor 1
Mid-point Frequency 1 of
01-03
Motor 1
01-04
Mid-point Voltage 1 of Motor 1
Mid-point Frequency 2 of
01-05
Motor 1
01-06
Mid-point Voltage 2 of Motor 1
Min. Output Frequency of
01-07
Motor 1
01-08
Min. Output Voltage of Motor 1
01-09
Start-Up Frequency
01-10
Output Frequency Upper Limit
01-11
Output Frequency Lower Limit
01-12
Accel. Time 1
01-13
Decel Time 1
01-14
Accel Time 2
01-15
Decel Time 2
01-16
Accel Time 3
01-17
Decel Time 3
01-18
Accel Time 4
01-19
Decel Time 4
01-20
JOG Acceleration Time
01-21
JOG Deceleration Time
01-22
JOG Frequency
01-23
1st/4th Accel/decel Frequency
S-curve Acceleration Begin
01-24
Time 1
S-curve Acceleration Arrival
01-25
Time 2
S-curve Deceleration Begin
01-26
Time 1
S-curve Deceleration Arrival
01-27
Time 2
Skip Frequency 1 (upper limit)
01-28
Skip Frequency 1 (lower limit)
01-29
Call 1(800)985-6929 for Sales
deltaacdrives.com
Chapter 10 Summary of Parameter Settings|C200 Series
Explanation
0.00~600.00Hz
0.00~600.00Hz
230V: 0.0V~255.0V
460V: 0.0V~510.0V
0.00~600.00Hz
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.00~600.00Hz
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.00~600.00Hz
230V: 0.0V~240.0V
460V: 0.0V~480.0V
0.00~600.00Hz
0.00~600.00Hz
0.00~600.00Hz
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
Pr.01-45=0: 0.00~600.00 second
Pr.01-45=1: 0.00~6000.0 second
0.00~600.00Hz
0.00~600.00Hz
Pr.01-45=0: 0.00~25.00 second
Pr.01-45=1: 0.0~250.0 second
Pr.01-45=0: 0.00~25.00 second
Pr.01-45=1: 0.0~250.0 second
Pr.01-45=0: 0.00~25.00 second
Pr.01-45=1: 0.0~250.0 second
Pr.01-45=0: 0.00~25.00 second
Pr.01-45=1: 0.0~250.0 second
0.00~600.00Hz
0.00~600.00Hz
deltaacdrives.com
Settings
10-5
sales@deltaacdrives.com
Factory
Setting
60.00/
50.00
60.00/
50.00
200.0
400.0
3.00
11.0
22.0
0.50
2.0
4.0
0.00
0.0
0.0
0.50
600.00
0.00
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
10.00
10.0
6.00
0.00
0.20
0.2
0.20
0.2
0.20
0.2
0.20
0.2
0.00
0.00