When D
Example
Remarks
1.
2.
Call 1(800)985-6929 for Sales
D1
D2
P
Word Devices
K
H KnX KnY KnM T
operand
2
: Start device of the range to be reset
1
> D
, only operands designated by D
1
2
1. When X0 = On, auxiliary relays M300 ~ M399 will be reset to Off.
2. When X1 = On, 16 counters C0 ~ C127 will all be reset (writing in 0; contact
and coil being reset to Off).
3. When X10 = On, timers T0 ~ T127 will all be reset (writing in 0; contact and coil
being reset to Off).
4. When X3 = On, data registers D0 ~ D100 will be reset to 0.
X0
X1
X10
X3
Devices, e.g. bit devices Y, M, S and Word Devices T, C, D, can use RST
instruction.
API 16 FMOV instruction is also to send K0 to Word Devices T, C, D or bit
registers KnY, KnM, KnS for reset.
X0
deltaacdrives.com
Zero Reset
16-bit command (5 STEPS)
C
D
ZRST
32-bit command
Flag signal: none
: End device of the range to be reset
D
2
will be reset.
2
ZRST
ZRST
ZRST
ZRST
RST
RST
RST
FMOV
14-55
deltaacdrives.com
sales@deltaacdrives.com
Chapter 14 PLC Function |C200 Series
ZRSTP
M300
M399
C0
C127
T0
T127
D0
D100
M0
T0
Y0
K0
D10
K5
sales@deltaacdrives.com