13.5 CANopen Fault Code
Display
Fault
ocA
Oc at accel
ocd
Oc at decel
Fault
ocn
Oc at normal SPD
Fault
GFF
Ground fault
Fault
occ
Short Circuit
Fault
ocS
Oc at stop
ovA
Ov at accel
Fault
ovd
Ov at decel
Fault
ovn
Ov at normal SPD
Call 1(800)985-6929 for Sales
deltaacdrives.com
Fault code
0001H
Over-current during acceleration
0002H
Over-current during deceleration
Over-current during steady status
0003H
operation
Ground fault. When (one of) the output
terminal(s) is grounded, short
circuit current is more than 50% of AC
0004H
motor drive rated current.
NOTE: The short circuit protection is
provided for AC motor drive
Protection, not for protection of the user.
Short-circuit is detected between upper
0005H
bridge and lower bridge of the
IGBT module.
Over-current at stop. Hardware failure in
0006H
current detection
Over-current during acceleration.
0007H
Hardware failure in current detection
Over-current during deceleration.
0008H
Hardware failure in current detection.
Over-current during steady speed.
0009H
Hardware failure in current detection.
230V: 450Vdc; 460V: 900Vdc
deltaacdrives.com
Chapter 13 CANopen Overview |C200 Series
Description
13-20
sales@deltaacdrives.com
CANopen
CANopen
fault
fault code
register
(bit 0~7)
2213 H
1
2213 H
1
2214H
1
2240H
1
2250H
1
2314H
1
3210H
2
3210H
2
3210H
2
sales@deltaacdrives.com