Settings
Over-voltage Stall
23
prevention Warning
Operation Mode
24
Indication
25
Forward Command
26
Reverse Command
Output when Current
27
>= Pr.02-33
Output when Current
28
<= Pr.02-33
Output when
29
frequency >=
Pr.02-34
Output when
30
Frequency <=
Pr.02-34
Y-connection for the
31
Motor Coil
  -connection for the
32
Motor Coil
Zero Speed (actual
33
output frequency)
Zero Speed with Stop
34
(actual output
frequency)
Error Output
35
Selection 1 (Pr.06-23)
Error Output
36
Selection 2 (Pr.06-24)
Error Output
37
Selection 3 (Pr.06-25)
Error Output
38
Selection 4 (Pr.06-26)
39
Reserved
Speed Attained
40
(including zero
speed)
41
Reserved
42
Crane Function
Motor Zero-speed
43
Output (Pr.02-47)
44
Low Current Output
45
Reserved
Master dEb signal
46
output
Brake Release at
47
Stop
Call 1(800)985-6929 for Sales
Functions
Active when the over-voltage stall prevention is detected.
Active when the operation command is controlled by external
terminal. (Pr.00-20≠0)
Active when the operation direction is forward.
Active when the operation direction is reverse.
Active when current is >= Pr.02-33.
Active when current is <= Pr.02-33.
Active when frequency is >= Pr.02-34.
Active when frequency is <= Pr.02-34.
Active when PR.05-24 is less than Pr.05-23 and time is more than
Pr.05-25.
Active when PR.05-24 is higher than Pr.05-23 and time is more than
Pr.05-25.
Active when the actual output frequency is 0. (the drive should be at
RUN mode)
Active when the actual output frequency is 0 or Stop.
Active when Pr.06-23 is ON.
Active when Pr.06-24 is ON.
Active when Pr.06-25 is ON.
Active when Pr.06-26 is ON.
Active when the output frequency reaches frequency setting or stop.
This function should be used with Pr.02-32, Pr.02-33 and Pr.02-34.
Active when setting Pr.07-16=Pr.02-34 and Fcmd > Pr.02-34 and
output current > Pr.02-33 and Time > Pr.02-32.
The example of the crane application is in the following for your
reference.
Active when motor actual speed is less than Pr.02-47.
This function needs to be used with Pr.06-71 ~ Pr.06-73
When dEb arise at Master, MO will send a dEb signal to Slave. Then
Slave will follow Master's command and decelerate to stop
simultaneously.
When drive stops, the corresponding multi-function terminal will be
ON if the frequency is less than Pr.02-34. After it is ON, it will be OFF
when brake delay time exceeds Pr.02-32.
deltaacdrives.com
Chapter 11 Description of Parameter Settings|C200 Series
Descriptions
11-35
deltaacdrives.com
sales@deltaacdrives.com
sales@deltaacdrives.com