Troubleshooting
Error Message
Description
No valid frame
No valid frame found during fast scan routine (after several retries). Make sure all
6261
found
frame specifications are applied.
No valid frame
6262
Only 1 frame point found during diagonal scan.
found
No valid frame
6263
No frame points found during diagonal scan.
found
No valid frame
6264
Thickness of left side of frame invalid
found
No valid frame
6265
Varying thickness
found
No valid frame
6266
Invalid thickness
found
No valid frame
6267
Invalid frame angle
found
No valid frame
6268
Requested X movement for fast scan cannot be executed.
found
No valid frame
6269
Invalid spot type
found
204
Solution
To check:
Frame isn't found within 120 cm.
Media space before frame bottom
is too much.
Frame bottom doesn't have the
correct specifications (minimum
thickness of 3mm on ALL sides,
thickness
too
varying,
frame
height < 20cm, frame width <
10cm, frame angle < 5°)
Refer to
Bounding box details on
page 152
AP-75370 - Revision 1.1