7.6.2 Steps of the OPC UA configuration

Steps of configuration
198
When using the Siemens TIA Portal, the OPC UA configuration happens by the following
steps:
1.
Create your project in the Siemens TIA Portal with the corresponding hardware con-
Ä Chap. 13.3 'TIA Portal - Hardware configuration - CPU' page 296
figuration.
2.
Configure the corresponding Ethernet connection for PG/OP communication and
establish an online connection.
Ethernet PG/OP channel' page 299
3.
Save translate and transfer your project.
transfer' page 320
4.
Call the external OPC UA Configurator from the Siemens TIA Portal. For this click
at 'Devices & networks' on the CPU of VIPA and select 'Start device tool' .
ð A dialog window opens. Select 'OPC UA Configurator' and click [Start].
5.
Ignore the query 'Set interface' with [OK]
ð The OPC UA Configurator is started.
6.
If not yet confirmed, you will now receive an access request in the TIA Portal.
Please note that due to the software the access request does not
appear in the foreground. To show the access request, you must
again bring the Siemens TIA Portal to the foreground. Once the
access has been selected, you must again bring the 'OPC UA
Configurator' to the foreground.
You have the following options for access:
n
'No' : Deny access - the OPC UA Configurator is not started.
n
'Yes' : Access is permitted once and the OPC UA Configurator is started.
n
'Yes to all' : Access is permitted and the OPC UA Configurator is started. At the
next call, the access request is no longer shown.
Allow access with 'Yes' respectively 'Yes to all' .
ð
NOTICE!
Data exchange between platforms of different vendors
If you allow access, you permit the exchange of data between
OPC UA Configurator and your project data of the Siemens TIA
Portal.
For the OPC UA configuration, the data is taken from the Siemens TIA Portal
project and listed in the table for the OPC UA configuration.
Please note that only the objects of the LD, FBD and IL lan-
guages can be transferred to the OPC UA Configurator.
7.
Configure the OPC UA server and the data for the OPC UA communication.
Ä Chap. 13.4 'TIA Portal - Hardware configuration -
Ä Chap. 13.10 'TIA Portal - Project
Ensure that the necessary security guidelines are complied
with.