VIPA System SLIO
Counter 0 ... 2
SW gate
Edge 0-1
Edge 0-1
5.6.6.3
Comparator
Function
HB300 | CPU | 013-CCF0R00 | en | 19-30
n
At interrupt function, the counter starts counting with the last recent counter value
after gate restart.
Gate function
Abort count process
Interrupt count process
In the CPU a comparison value may be stored. During the counting procedure the
counter value is compared with the comparative value. Depending on the result of the
comparison the output channel of the counter and the status bit of STS_CMP of SFB 47
can be set. In addition, you can configure a hardware interrupt. A comparison value can
be specified via the parametrization respectively the job interface of SFB 47.
Deployment I/O periphery
Counting > Counter - Additional functions
Reaction counter 0 ... 2
Restart with load value
Continue
143