With the operation field "OB82 / I/O fault task..." you can cause the CPU to call the OB 82
at an error event of the PROFINET interface. An entry to the diagnostics buffer is always
done. The other parameters here are not relevant for the use of the VIPA PROFINET
CPU.
These settings are not required for the use of the PROFINET IO controller as an I-Device
and should not be changed.
page 238
These settings are not relevant and should not be changed.
MRP is supported exclusively as a redundancy client.
In this area you can configure time-of-day master for time-of-day synchronization in the
Ä Chap. 4.7.1.1.1 'Time-of-day synchronization' page 75
network.
Here you can set the interval time with which "Keep-Alive" telegrams are to be sent to a
connection partner. This ensures that a communication partner can still be reached
because the connection resources are automatically released again after the expiration
interval time.
Shown is the short name "Port...". In the field Name another designation may be selected,
which is also shown in the configuration table At comment you may describe your entry
near more. The comment also appears in the configuration table.
Via the port address the diagnostics information of the IO controller may be accessed.
These parameters serve for the port setting for topology
page 246
These parameters serve for the port setting. Here the following parameters are sup-
ported:
n
Connection
Here you can make settings for transmission medium and type. Ensure that the
setting for the local port and the partner port are identical.
PROFINET requires 100Mbit/s in duplex mode.
Boundaries
n
Boundaries are limitations for the transfer of certain Ethernet frames. The fol-
lowing Boundaries are supported:
'End of detection of accessible nodes' : DCP frames for detecting accessible
nodes are not forwarded. When enabled, participants which are lying behind this
port, are no longer recognized and can not be reached by the controller.
'End of topology discovery' : When enabled, this port does not support topology
discovery, i.e. LLDP frames are not forwarded.
Ä Chap. 10.4 'Deployment as PROFINET I-Device'