5.6.6.5
Counter output channel
Characteristics of the
output
5.6.6.6
Hysteresis function
Hysteresis
HB300 | CPU | 013-CCF0R00 | en | 19-30
Each counter has an output channel. You pre-define the behavior of the counter output
via the parametrization:
no comparison:
n
The output is used as normal output.
SFB 47:
The input parameter CTRL_DO is effect less.
The status bits STS_DO and STS_CMP (status comparator in the instance DB)
remain reset.
Counter value ³ comparison value respectively counter value £ comparison value
n
The output remains set as long as the counter value is higher or equal compar-
ison value respectively lower or equal comparison value.
SFB 47:
Control bit CTRL_DO must be set.
The comparison result is shown by the status bit STS_CMP. This status bit may
only be reset if the comparison condition is no longer fulfilled.
n
Pulse at comparison value
When the counter reaches the comparison value the output is set for the parame-
trized pulse duration. When you've set a main counting direction the output is only
set at reaching the comparison value from the main counting direction.
If the pulse duration = 0, the output is set until the comparison condition is not
longer fulfilled.
SFB 47:
Control bit CTRL_DO must be set.
The status of the digital output may be shown by the status bit ST_DO.
The comparison result is shown by the status bit STS_CMP. The bit may only be
reset if the pulse duration has expired.
n
Pulse duration
The pulse duration starts with the setting of the according digital output.
The inaccuracy of the pulse duration is less than 1ms.
There is no past triggering of the pulse duration when the comparison value has
been left and reached again during pulse output.
If the pulse duration is changed during operation, it will take effect with the next
pulse.
If the pulse duration = 0, the output is set until the comparison condition is not
longer fulfilled.
Range of values: 0...510ms in steps of 2ms
n
The hysteresis serves the avoidance of many toggle processes of the output and the
interrupt, if the counter value is in the range of the comparison value.
n
For the hysteresis you may set a range of 0 to 255.
n
The settings 0 and 1 deactivate the hysteresis.
n
The hysteresis influences zero run, comparison, over- and underflow.
n
An activated hysteresis remains active after a change. The new hysteresis range is
activated with the next hysteresis event.
The following pictures illustrate the output behavior for hysteresis 0 and hysteresis 3 for
the according conditions:
Deployment I/O periphery
Counting > Counter - Additional functions
145