VIPA System SLIO
Parameter
HB300 | CPU | 013-CCF0R00 | en | 19-30
n
Miscellaneous
Direct DX transition
PN MultipleWrite
Free Module Mapping
Reduced PDU size
Ä 90
n
Access settings
CPU
Activation of interfaces and ports
Activation of protocols
The following parameters may be accessed by means of the properties dialog of the
CPU.
Diagnostics interrupt (default: deactivated)
n
Diagnostics interrupt 5L+ (DC 24V DI power section supply)
n
Diagnostics interrupt 2L+ (DC 24V DO power section supply)
n
Diagnostics interrupt 3L+ (DC 24V System SLIO bus power section supply)
Diagnostics interrupt DO short circuit/overload
n
n
Diagnostics interrupt sensor short circuit/overload
MPI
n
Function X3
Functionality of the MPI(PtP) interface X3
MPI/DP (default): In this operating mode parameters are active, which you set on
sub module 'MPI/DP' of the Siemens CPU 314C-2 PN/DP.
Deployment PROFIBUS communication' page 254
PTP: With this operating mode the RS485 interface acts as an interface for serial
point-to-point communication. Here data may be exchanged between two stations
by means of protocols.
Retentive data
n
Additional retentive memory
Here enter the number of retentive memory bytes. With 0 the value
'Retentive memory è Number of memory bytes starting with MB0' is set, which is
pre-set at the parameters of the Siemens CPU.
Range of values: 0 (default) ... 8192
n
Additional retentive timer
Enter the number of S7 timers. With 0 the value 'Retentive memory
è Number S7 timers starting with T0' is set, which is pre-set at the parameters of
the Siemens CPU.
Range of values: 0 (default) ... 512
n
Additional retentive counter
Enter the number of S7 counter. With 0 the value 'Retentive memory
è Number S7 counters starting with C0' is set, which is pre-set at the parameters
of the Siemens CPU.
Range of values: 0 (default) ... 512
OB
Priority OB 57
n
Here you can set the priority for the OB 57.
Range of values: 2 (default) ... 24
n
OB 80 for cyclic interrupt error
Here you can set for which cyclic interrupt OB 80 (time error) should be called.
Range of values: Deactivated (default), selection of the corresponding OB
Setting VIPA specific CPU parameters
Ä 85
Ä Chap. 6 'Deployment PtP communication' page 170
Deployment CPU 013-CCF0R00
Ä Chap. 11 'Option: