Deployment OPC UA
Usage OPC UA Configurator > Device properties
7.7.3.3
Communication settings
Setting the Ethernet inter-
face
202
Click on the input field and enter any comment, e.g. an annotation or explanation.
With the [Enter] key, you can add a new line to the input field.
The communication settings are used to configure the interface for the data exchange
between programming device and destination station. Since the IP address parameters
for the OPC UA configuration are imported from the project, you simply have to set the
interface via which you are connected to the destination station.
1.
Click in the project tree at 'Device properties' .
ð The editor of the 'Device properties' opens.
2.
Select the area 'Communication settings' .
1.
'Active PC interface' : Select 'Ethernet interface' .
2.
'PC interface' : Select the network adapter for the communication connection from
the list.
ð If an IP address is already configured in the network adapter, it is shown under
the input field 'IP address' . If necessary, select a different IP address.
3.
'CPU interface' : Select the interface of the control from the list.
ð Since the IP address is imported from the project, it is shown below the input
field.
4.
To configure further settings of the interface, click on 'Interface configuration' .
ð The 'Interface properties' dialog window will open.
VIPA System SLIO
HB300 | CPU | 013-CCF0R00 | en | 19-30