Event ID
0xED30
0xED31
0xED40
0xED50
0xED60
HB300 | CPU | 013-CCF0R00 | en | 19-30
Description
0: There is no EC configuration
1: There is an EC configuration
ZINFO3: DC in sync
0: Not in sync
1: In sync
EtherCAT: Topology deviation
ZINFO2: Diagnostic address of the master
EtherCAT: Overflow of the interrupt queue
ZINFO2: Diagnostic address of the master
Bus cycle time infringement occurred
ZINFO1: Logical address of the IO system
EtherCAT: Distributed clocks (DC) in sync
OB: Operating mode
0: Configuration in operating condition RUN
1: STOP (update)
2: STOP (memory reset)
3: STOP (auto initialization)
4: STOP (internal)
5: STARTUP (cold start)
6: STARTUP (restart/warm start)
7: STARTUP (hot restart)
9: RUN
10: HALT
11: COUPLING
12: UPDATING
13: DEFECTIVE
14: Error search mode
15: De-energised
253: Process image release in STOP
254: Watchdog
255: Not set
ZINFO2: Diagnostic address of the master
ZINFO3: DC state change
0: Master
1: Slave
EtherCAT: Diagnostic buffer CP: Slave status change
OB: Operating mode
0: Configuration in operating condition RUN
System specific event IDs