Configuration
13.6.2.2
Installation of the GSDML files
Proceeding
HB300 | CPU | 013-CCF0R00 | en | 19-30
TIA Portal - Deployment PG/OP communication - PROFINET > Deployment as PROFINET I-Device
The I-Device (Intelligent IO device) functionality of a CPU allows data to be exchanged
with an IO controller, which are preprocessed by the CPU. In this case, the I-Device is
connected as an IO device to a higher-level IO controller. The process values, recorded
in central or decentralized periphery, can be preprocessed via a user program and made
available to the higher-level PROFINET IO controller by means of PROFINET.
n
The configuration of the integrated PROFINET IO controller of the CPU as an I-
Device is made via a virtual PROFINET devices, which is to be installed by means of
a GSDML from VIPA in the hardware catalog.
n
The communication takes place via input/output areas, which are defined in the I-
Device.
n
The size of the areas for input and output data is max. 768byte.
n
The I-Device is made available to a deterministic PROFINET IO system via a
PROFINET IO interface and thus supports the real-time communication Real-Time .
n
The I-Device functionality meets the requirements of the RT class I (A) and corre-
sponds to the PROFINET specification version V 2.3.
n
In order for the higher-level IO controller to communicate with the VIPA I-Device, the
following must be observed:
I-Device and higher-level IO controllers must be configured in different networks.
Their IP addresses must be in the same IP circuit.
The device name of the PROFINET controller of the I-Device must match the
device name of the I-Device at the higher-level IO controller.
The configuration of the PROFINET IO controller as I-Device should be done by the fol-
lowing procedure:
1.
Installation of the GSDML files
2.
Configuration as I-Device
3.
Configuration in the higher-level IO controller
The following GSDML files are required for configuring the integrated PROFINET I-
Device in the Siemens TIA Portal:
n
GSDML for I-Device
n
GSDML for I-Device at IO controller
The installation of the PROFINET IO device 'VIPA SLIO CPU' happens in the hardware
catalog with the following approach:
1.
Go to the service area of www.vipa.com.
2.
Download from the download area at 'Config files è PROFINET' the according file
for your System SLIO.
3.
Extract the file into your working directory.
4.
Start the Siemens TIA Portal.
5.
Close all the projects.
6.
Switch to the Project view.
7.
Select 'Options è Install general station description file (GSD)'.