Deployment I/O periphery
Counting > Counter - Additional functions
5.6.6.4
Additional functions counter 3
5.6.6.4.1
HW gate via Gate 3
Counter 3:
SW gate
HW gate
Edge 0-1
de-activated
Edge 0-1
de-activated
Edge 0-1
1
1
Edge 0-1
Edge 0-1
1
1
Edge 0-1
Counter 3 - count once
If the internal gate has been closed automatically it may only be opened again under the following conditions:
SW gate
1
Edge 0-1 (after edge 0-1 at HW gate)
5.6.6.4.2
Latch function
Function
144
Exclusively counter 3 has the following additional functions:
n
HW gate via Gate 3
n
Latch function
Starting, stopping and interrupting a count function of counter 3 happens via the internal
gate (I gate). The i gate is the result of logic operation of HW gate and SW gate. The HW
gate evaluation of the connection 'Gate 3' may be deactivated by the parametrization.
With a de-activated HW gate evaluation the triggering exclusively happens by setting the
SW gate of SFB 47.
Gate function
Abort count process
Interrupt count process
Abort count process
Abort count process
Interrupt count process
Interrupt count process
As soon as during a count process an edge 0-1 is recognized at the "Latch" input of
n
counter 3, the current counter value is stored in the according latch register.
n
You may access the latch value via the parameter LATCHVAL of SFB 47.
n
A just in LATCHVAL loaded value remains after a STOP-RUN transition.
Reaction counter 3:
Restart with load value
Continue
Continue
Restart with load value
Continue
Continue
HW gate
Edge 0-1
Edge 0-1
HB300 | CPU | 013-CCF0R00 | en | 19-30