Adding or Removing Cabinet Hardware
4. Follow the Install Shield procedure to transfer all the necessary files to the
TN802 IP Interface.
NOTE:
In the Finish dialog box, select I will restart later. Do not
select Restart computer.
This would be a good time to read the Readme.txt file.
5. Click on Start > Settings > Control Panel > Services.
6. Select IP Trunk and click on Startup.
NOTE:
Do not click on Start.
7. Under Startup Type, select Disabled and click OK to disable IP Trunk
mode.
NOTE:
If IP trunk and MedPro services are both set to automatic, the
TN802B defaults to IP Trunk and MedPro features cannot be used.
8. Select MedPro and click on Startup.
NOTE:
Do not click on Start.
9. Under Startup Type, select Automatic and click OK to enable MedPro
mode.
10. Click Start > Shut Down and select Restart the computer?
or on the TN802:
Press the recessed reset button on the faceplate (see
LCD shows a flashing MSHUT *. When the flashing stops and the asterisk
disappears (about 2 min), reseat the circuit pack to restart the system.
or on the SAT:
a. Type busyout board UUCSS and press
b. Type reset board UUCSS and press
c. Type release board UUCSS and press
Once the system is completely initialized, the LCD reads MEDPRO *.
!
WARNING:
When connected remotely via pcANYWHERE, only use the
pcANYWHERE Restart Host Computer button on the toolbar to
restart Windows NT.