Avaya DEFINITY Server R Manual page 169

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Interconnect Port Networks with Fiber Optic Cabling
High Reliability
NOTE:
Keep track of which fiber attaches to which connector on each lightwave
transceiver.
This section provides figures showing typical ways of making these connections.
The connectors on the lightwave transceivers are labeled TX (transmit) or RX
(receive), while the fibers attaching to each connector are numbered 1 or 2. See
Figure
4-13.
Collocated Port Networks
For a high reliability system with 1 collocated EPN, use 1 fiber optic cable and 2
lightwave transceivers, or 1 single-mode fiber optic cable and 2 single-mode
lightwave transceivers to directly connect the networks.
For a high reliability system with 2 collocated EPN, use 3 fiber optic cables and 6
lightwave transceivers, or 3 single-mode fiber optic cables and 6 single-mode
lightwave transceivers to directly connect the networks.
NOTE:
Based on floor plan considerations, the length of these cables may vary.
20-foot (6.1 m) cables are normally adequate for 2 port networks.
For collocated cabinets, route the fiber optic cables directly from the PPN to each
EPN cabinet. Since the PPN cabinet (MCC1) is collocated with a Single-Carrier
Cabinet stack (SCC1), the preferred routing is to run the cables down the cable
tray and out the bottom of the PPN cabinet. The cables are then run to the EPN
cabinet and up the outside of the rear panels to the desired carrier.
Fiber-Remoted Port Networks
For a high reliability system with 1 fiber-remoted EPN, use 2 fiber optic cables, 2
lightwave transceivers, and 2 lightguide interface units (provided by the PSC).
For a high reliability system with 2 fiber-remoted EPNs, use 6 fiber optic cables, 6
lightwave transceivers, and 6 lightwave-interface units (provided by the PSC).
DS1 CONV-Remoted Port Networks
For a high reliability system with 1 DS1 CONV-remoted expansion port network,
use 2 DS1 CONV circuit packs (TN1654), 2 DS1 CONV-to-EI cables (846448637
and/or 846448645), 2 H-600-348 cables, from 1 to 4 pairs of channel service units
(CSUs), and from 1 to 4 pairs of wall-field cables (provided with the CSUs).
NOTE:
The TN1654 requires a TN573B Switch Node Interface circuit pack
555-233-115
Issue 7 November 2003
4-45