Change Cabinet Address Plugs - Avaya DEFINITY Server R Manual

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Install the EPN
3. Install the port circuit packs into the A cabinet using the label on the front of
the carrier and the annotated list of circuit packs as a guide.
NOTE:
Because the new expansion control carrier has 6 more port slots than
the one removed, you do not need to retranslate these circuit packs.
4. For an EPN in a high or critical reliability system, install a TN2182B
Tone-Clock and a TN570 EI in slots 1 and 2 of port cabinet B. See
4-5.
'
Table 4-5. TN570 Expansion Interface Requirements
2 PNs w/o Critical
Cabinet
Reliability
PPN
1
EPN 1
1
EPN 2
N/A

Change Cabinet Address Plugs

If a duplicated control cabinet was removed from position B and was not replaced
with a new port cabinet, the upgraded EPN's port cabinets occupy different
positions in the cabinet stack.
1. Behind each port cabinet, find the address plug attached to 2 of the 6
backplane pins to the right of the pin-field block for slot 00.
2. Change the location of each port cabinet address plug to reflect the
cabinet's current position. See
555-233-115
2 PNs w/Critical
3 PNs w/o Critical
Reliability
Reliability
2
2
N/A
Figure
4-1.
3 PNs w/Critical
Reliability
2
4
2
4
2
4
Issue 7 November 2003
Table
4-21

Advertisement

Table of Contents
loading

Table of Contents