Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya Communication
Manager
8. For an AC-powered system, install the 2 new carrier ground straps. One
strap connects ground point "1" to the A-carrier frame (right side), and the
other connects ground point "8" to the A-carrier frame (left side).
NOTE:
DC-powered carriers do not use these carrier ground straps.
9. Connect the remaining end of the TDM/LAN cable (between the "A" and
"D" carriers) to the pin-field block marked "TDM" on the right side of the "A"
carrier. See
to the "D" carrier when the old carrier was removed.
10. Connect the remaining end of the TDM/LAN cable (between the "A" and
"C" carriers) to the pin-field block marked "TDM" on the left side of the "A"
carrier. The other end remained connected to the "C" carrier when the old
carrier was removed.
11. On port carrier J58890BB-1, connect the TDM cable or TDM terminator to
Slot 02. On port carriers J58890BB-2 and J58890BB-3, connect the TDM
cables to Slot 01.
5-50
Issue 7 November 2003
Figure 5-8
and
Table
5-13. The other end remained connected
555-233-115