Administer No-License/Emergency Numbers; Restart Definity Lan Gateway System; Label Main Distribution Frame; Reconnect Cables - Avaya DEFINITY Server R Manual

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading R5si/R6si to an Avaya DEFINITY Server R
EPN running Avaya Communication Manager

Administer No-License/Emergency Numbers

1. At the SAT type change system-parameters features and press
The Feature-Related System Parameters screen displays.
2. In the Emergency Numbers - Internal field (optional) type a valid
extension.
NOTE:
This number cannot be a hunt group or ACD number.
3. In the Emergency Number - External field (required) type a 21-digit,
dialpad-valid character string that can include trunk access codes. The
default for this field is 911.
4. In the No-License Incoming Call Number field (optional) type a valid
extension.
NOTE:
This number cannot be a hunt group or ACD number.
5. Press

Restart DEFINITY LAN Gateway System

1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select Maintenance > Reset System >
Restart System.

Label Main Distribution Frame

1. Label the MDF with the new PN number of the new EPN. The STS
software upgrade assigns the next PN number, after the highest numbered
PN in the Release 5/6si system, to the upgraded EPN.

Reconnect Cables

1. Behind each EPN cabinet power supply, set the circuit breaker to OFF.
NOTE:
Powering down an EPN cabinet without powering down the PPN will
set off alarms. However, these alarms should clear after power is
restored to the EPN.
2. Replace all cables that were labeled and removed.
4-30
Issue 7 November 2003
to save the changes.
ENTER
.
RETURN
555-233-115