Task Table
All:
2. In the UPDATE FILE section, check the Update State field for a software
patch:
NOTE:
If you need to restore the system to the old software version, you
must also download a patch onto the system.\
3. In the SOFTWARE VERSION section note the current software version
listed in the Memory Resident field.
NOTE:
Ensure that the memory, removable media, and disk software loads
and translations are current and that the current software version is
compatible with this software-only upgrade path.
Disable Scheduled Maintenance and Alarm
Origination
To prevent scheduled daily maintenance from interfering with the upgrade:
1. To prevent scheduled daily maintenance from interfering with the update or
upgrade, type change system-parameters maintenance and press
RETURN
2. If scheduled maintenance is in progress, set the Stop Time field to 1
minute after the current time.
or
If scheduled maintenance is not in progress, set the Start Time field to a
time after the upgrade will be completed.
For example, if you start the upgrade at 8:00 P.M. and the upgrade takes
90 minutes, set the Start Time field to 21:30.
!
CAUTION:
If you do not disable Alarm Origination, the system can generate
alarms, resulting in unnecessary trouble tickets.
3. Type neither in the Alarm Origination to OSS Numbers field and
press
555-233-115
If there is a patch number, then a patch has been applied.
If the field is none in memory, there is no software patch in
system memory.
.
ENTER.
Issue 7 November 2003
1-19