Adding or Removing Cabinet Hardware
5. Check the Code column to see if the slots above the TN802B say
DSMAPD or MEDPRO.
.
change circuit-packs
Cabinet: 1
Slot Code
01: TN754
02: TN758
03: TN2144
04: TN746
05
06: TN771
07: TN464
08: TN2140
09: TN767
10: TN799
'#' indicates circuit pack conflict.
6. If not, type MEDPRO in the slot just above TN802B slot and press
Changing the one entry automatically changes the entry above it. If it is in
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
7. Type change ip-interfaces and press
8. Type in the information for the TN802B IP Interface,
9. Set the Enabled field to y, and press
NOTE:
The customer provides the IP address, subnet mask, and gateway
address.
At this time the TN802B LCD reads PC BOOT *, and about 3 to 4 minutes
later reads MEDPRO * with the asterisk flashing
7-72
Issue 7 November 2003
CIRCUIT PACKS
Sf Mode
Name
DIGITAL LINE
POOLED MODEM
ANALOG LINE
B
ANALOG LINE
C
MAINTENANCE/TEST
F
DS1 INTERFACE
E&M TIE TRUNK
E
DS1 INTERFACE
B
CONTROL-LAN
Page
Carrier: A
Carrier Type: processor
Slot Code
Sf Mode
11:
MEDPRO
RESERVED-IP
12:
MEDPRO
RESERVED-IP
13:
TN802
B
14:
15:
16:
.
Enter
.
Enter
555-233-115
1 of
5
Name
MAPD BOARD
.
Enter