Upgrade Firmware on Programmable Circuit Packs
4. Record the UUCSS address in the Board Number field of each source and
target circuit pack.
If a C-LAN is the source, make sure port 17 is assigned on that C-LAN. If it
is not assigned, administer the port.
5. Type add data-module UUC17 and press
For a self download to a VAL board, make sure that port 33 is assigned on
the VAL board. If it is not assigned, administer the port.
6. Type add data-module UUC33 and press
7. Determine the IP address of the source circuit pack. You can either ask the
data systems administrator or type the following commands:
a. Type display ip-interfaces. Find the source circuit pack's Slot
b. Type display node-names ip. Find the source circuit pack's Node
Set up source circuit pack's file system
Before files can be copied to the source circuit pack, you must set up a file system
on the source circuit pack to accept the files.
1. Log in using a superuser or services login and password.
2. Type enable filesystem board UUCSS login ftplogin ftppassword,
where:
You use this same ftplogin and ftppassword in the section,
file to source'' on page
This completes the preparation for a firmware download.
555-233-115
location and write down its Node Name.
Name and write down its IP Address.
UUCSS is the location of the source circuit pack.
ftplogin is any temporary login ID that you choose for this FTP
session (for example, denver).
ftppassword is any password that you choose for this FTP session
(for example, broncos). The password must be at least 7 characters
long.
7-12.
.
Enter
.
Enter
''FTP the image
Issue 7 November 2003