Avaya DEFINITY Server R Manual page 473

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Add IP Solutions
Install the circuit packs
1. If replacing the TN799 circuit pack, install the TN799B/C circuit pack in the
slot vacated by the TN799 circuit pack.
2. For convenience install the TN2302AP circuit pack in the rightmost slot
vacated by the TN802B and where the adapter is connected to the
corresponding backplane connector. The other 2 slots are now available for
other circuit packs.
When you plug in the TN2302AP IP Media Processor, the circuit pack starts to
boot. The RED LED stays on until an IP address is assigned to the circuit pack.
3. Type list configuration all and press
recognizes the TN2302AP circuit packs.
Administration Steps
1. Administer the TN799B/C C-LAN, if necessary. Refer to the Administration
for Network Connectivity for Avaya Communication Manager.
2. Administer the IP Media Processor, which is usually done remotely. Call
your service representative to start the process.
3. Complete the administration and testing. Refer to
Steps for C-LAN and IP Media Processor'' on page 7-56
External Connection to the LAN'' on page
Add IP Interface Assembly
The IP Interface is an assembly composed of a TN802B circuit board, a processor
card, and DSP resource card. For ordering purposes, the assembly is identified as
a J58890MA-1 L30, but for simplicity, we refer to it as the TN802B IP Interface.
The TN802B IP Interface operates in two modes: IP Trunk, available with Release
7 or later, and Media Processor (MedPro), available with Release 8. The IP Trunk
mode is Internet Telephone Server—Enterprise (ITS-E) compatible, and the
MedPro mode is H.323 V2 compatible. The TN802B IP Interface is backwards
compatible and defaults to IP Trunk mode.You must administer it to use it in
MedPro mode.
The following sections describe the process for
Installing in Media Processor Mode
Installing in IP Trunk Mode
Upgrading a TN802 V3 (or later) to a TN802B (MedPro mode)
!
WARNING:
When connected remotely via pcANYWHERE, only use the pcANYWHERE
Restart Host Computer button on the toolbar to restart Windows NT.
555-233-115
to verify that the system
Enter
''Initial Administration
and
''Test the
7-58.
Issue 7 November 2003
7-63

Advertisement

Table of Contents
loading

Table of Contents