Adding or Removing Cabinet Hardware
Installing in Media Processor Mode
To operate in MedPro mode, you must install the TN802B IP Interface and, if the
system does not have one, you must also install and administer a TN799B C-LAN
circuit pack. For C-LAN administration, refer to Administration for Network
Connectivity for Avaya Communication Manager.
If you have existing TN802 IP Interface circuit packs, you can upgrade them either
by replacing the circuit pack with a TN802B or by downloading the TN802B
firmware onto the circuit packs (see
Prepare for Installation
Have the following equipment on site before your shipment arrives:
AC power outlets for the modem and monitor.
Three unoccupied and adjoining port slots in the carrier for the TN802B IP
Interface, if needed.
The TN802B occupies only one slot, but it needs the two slots to its left for
clearance.
An additional unoccupied port slot for the TN799B, if needed. If you have
an existing TN799 circuit pack, replace it with the TN799B.
A 10 BaseT or 10/100 BaseT Ethernet connection into your local area
network for the TN802B.
A 10 BaseT Ethernet connection into your local area network for the
TN799B.
Two or more valid, unused IP addresses on your network (one for MedPro
and one for C-LAN) that can be assigned to the IP Interface server. You
also need the subnet mask and default gateway.
An analog telephone line reserved (DID is okay) for the IP Interface
diagnostic modem
A valid telephone number reserved for the IP Interface diagnostic modem
In addition if non-U.S. customer:
Modem comparable to a U.S. Robotics Sportster Model USR 33.6 EXT.
Cable from modem to TN802B external cable assembly.
We recommend that you protect your cabinet with an uninterruptible power
system (UPS).