Complete the Upgrade

Copy Announcements (if necessary)

1. If the system contains a TN750/B Announcement circuit pack, type display
announcements and press
2. If administered recorded announcements are listed, type copy
announcements and press
NOTE:
The TN750C Announcement circuit pack stores announcements in
non-volatile memory; saving the announcements is not needed.
Complete the Upgrade
Install Remaining Hardware and Administer the
System
If the present system was removed to make room for the MCC1 cabinet, skip to
Step 3.
If the MCC1 cabinet was installed while the present system is in service, return to
''Remove the Present System'' on page
finished.
1. Connect all new and reusable I/O cables to the MCC1 cabinet.
Cross-connect at the MDF as required.
2. Remove all reusable circuit packs from the present system and install into
the MCC1 cabinet. Install any new circuit packs in the cabinet.
3. Install fiber optic cables and administer the fiber links as needed. Refer to
the Made Easy tools.
4. Administer any new translations, as required.

Resolve Alarms

1. Type display alarms and press
any alarms.

Check Link Status

1. Type display communication-interface links and press
with the earlier status.
2. Type status link number and press
555-233-115
.
Enter
.
Enter
3-10. Return to this section when
to examine the alarm log. Resolve
Enter
. Repeat this step for each link.
Enter
Issue 7 November 2003
. Compare it
Enter
3-19