Appendix A: Motor rotor
inertia, IEC
The table given below is an example of common inverter duty AC motor rotor inertia.
The data is from the ABB cast iron totally enclosed squirrel cage motors catalog.
The electrical ratings are based on 400 V AC 50 Hz sinusoidal input.
Power
Poles
(kW)
0.75
6
4
2
1.1
6
4
2
1.5
6
4
2
2.2
6
4
2
3
6
4
2
4
6
4
2
Base rpm
IEC Frame
935
90 S6
1410
80 M4
2830
80 M2
920
90 L6
1410
90 S4
2835
80 M2
950
100 L6
1410
90 L4
2850
90 S2
950
112 M6
1425
100 L4
2840
90 L2
955
132 S6
1415
100 L4
2870
100 L2
955
132 M6
1435
112 M4
2880
112 M2

Appendix A: Motor rotor inertia, IEC 671

14
Nominal
Nominal
current
torque
(A)
(Nm)
2.05
7.65
1.85
5
1.6
2.53
2.8
11.5
2.65
7.45
2.25
3.7
3.8
15
3.45
10.1
3.0
5.0
5
22
4.6
14.7
4.3
7.4
6.5
30
6.1
20.2
5.8
10
8.8
40
8
26.6
7.6
13
Inertia
2
(kgm
)
0.0039
0.0021
0.00097
0.0049
0.0029
0.0012
0.011
0.0037
0.0015
0.017
0.0075
0.002
0.038
0.0098
0.0044
0.049
0.014
0.0075