424 Parameters
No.
Name/Value
75.67
Speed match trim
-32767.0...
32767.0 rpm
75.89
Speed reference
status
Bit
Name
0
Counter direction
1
Accelerating
2
Decelerating
3
Ref on target
4
Stopping
5
Speed ref balancing
6
Reserved
7
Stop-ramp active
8
Speed additive ON
9
Speed matching ON
10
Reserved
11
Threading forward
12
Threading reverse
13...14 Reserved
15
Unwinding
0b0000...0b1111
Description
Displays the motor speed additive term, i.e the product of
speed matching parameter settings (parameters 75.36...
75.37).
This parameter is read-only.
Motor speed additive term.
Displays status of the winder speed settings group functions.
Description
1 = Line speed reference is negative.
0 = Line speed reference is positive or stopped.
1 = Accelerating now.
0 = Not accelerating.
1 = Decelerating now.
0 = Not decelerating.
1 = Line reference ramped is on target.
0 = Line reference ramped has not reached the target.
1 = Drive is performing a ramped stop.
0 = Drive is not performing a ramped stop.
1 = Ramp output is preset to actual speed.
0 = Normal ramping operation.
1 = Stop-ramp is activated.
0 = Stop-ramp is not activated.
1 = Tension control mode required speed additive.
0 = Speed additive is not used.
1 = Speed matching is enabled.
0 = Speed matching is disabled.
1 = Threading forward now.
0 = Not threading forward.
1 = Threading reverse now.
0 = Not threading reverse.
1 = Speed reference sign is for Unwinding.
0 = Speed reference sign is for Winding.
Status word.
Def/FbEq16
0.0 rpm
10 = 1 rpm
0b0000