ABB ACS880 Firmware Manual page 335

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
Speed ref ramped
Speed ref used
Torq ref used
Freq ref used
Process PID out
Process PID fbk
Process PID act
Process PID dev
Other
36.02
PVL filter time
0.00 ... 120.00 s
36.06
AL2 signal source
Zero
Motor speed used
Output frequency
Motor current
Motor torque
DC voltage
Power inu out
Speed ref ramp in
Speed ref ramped
Speed ref used
Torq ref used
Freq ref used
Process PID out
Process PID fbk
Process PID act
Process PID dev
Ambient
temperature
Other
Description
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
40.02 Process PID feedback actual
40.03 Process PID setpoint actual
40.04 Process PID deviation actual
Source selection (see
Terms and abbreviations
page 152).
Defines a filtering time for the peak value logger. See
parameter
36.01 PVL signal
Peak value logger filtering time.
Selects the signal to be monitored by amplitude logger 2.
The signal is sampled at 200 ms intervals, and can be
scaled using parameter
The results are displayed by parameters 36.40...36.49.
Each parameter represents an amplitude range, and shows
what portion of the samples fall within that range.
Amplitude logger 2 can be reset using parameter
Reset
loggers. The logger is also reset whenever the signal
source or scaling is changed. The date and time of the last
reset are stored into parameters
respectively.
None (amplitude logger 2 disabled).
01.01 Motor speed used
01.06 Output frequency
01.07 Motor current
(page 156).
01.10 Motor torque
(page 156).
01.11 DC voltage
(page 156).
01.14 Output power
(page 157).
23.01 Speed ref ramp input
23.02 Speed ref ramp output
24.01 Used speed reference
26.02 Torque reference used
28.02 Frequency ref ramp output
40.01 Process PID output actual
40.02 Process PID feedback actual
40.03 Process PID setpoint actual
40.04 Process PID deviation actual
01.70 Ambient temperature
The amplitude range of 0...100% corresponds to 0...60 °C or
32...140 °F.
Source selection (see
Terms and abbreviations
152).
(page 257).
(page 263).
(page 279).
(page 286).
(page 341).
(page 341).
(page 341).
(page 341).
source.
36.07 AL2 signal
scaling.
36.50
and
36.51
(page 156).
(page 156).
(page 257).
(page 257).
(page 263).
(page 279).
(page 286).
(page 341).
(page 341).
(page 341).
(page 341).
(page 159).
Parameters 335
Def/FbEq16
11
12
13
14
16
17
18
19
on
-
2.00 s
100 = 1 s
Ambient
temperature
36.09
0
1
3
4
6
7
8
10
11
12
13
14
16
17
18
19
20
on page
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents