406 Parameters
No.
Name/Value
ACS800 System ctrl
SW
Other
61.02
M/F data 2 selection
61.03
M/F data 3 selection
61.25
M/F data 1 value
0...65535
61.26
M/F data 2 value
0...65535
61.27
M/F data 3 value
0...65535
61.45
Data set 2 data 1
selection
None
CW 16bit
SW 16bit
Act1 16bit
Act2 16bit
Description
A follower status word compatible with an ACS800 (System
Control Program) master. With this setting, status word bit 0
is cleared whenever the run enable signal is missing.
Source selection (see
Terms and abbreviations
152).
Preselects the data to be sent as word 2 onto the
master/follower link.
See also parameter
61.26 M/F data 2
For the selections, see parameter
selection.
Preselects the data to be sent as word 3 onto the
master/follower link.
See also parameter
61.27 M/F data 3
For the selections, see parameter
selection.
Displays the data to be sent onto the master/follower link as
word 1 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly into this
parameter.
Data to be sent as word 1 in master/follower communication.
Displays the data to be sent onto the master/follower link as
word 2 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly into this
parameter.
Data to be sent as word 2 in master/follower communication.
Displays the data to be sent onto the master/follower link as
word 3 as an integer.
If no data has been preselected by
selection, the value to be sent can be written directly into this
parameter.
Data to be sent as word 3 in master/follower communication.
Parameters
61.45...61.50
sets 2 and 4 to the external controller. These data sets are
used in ModuleBus communication with a "standard drive"
(60.50 DDCS controller drive type
Parameters
61.95...61.100
external controller. If no data has been preselected, the
value to be sent can be written directly into these
parameters.
For example, this parameter preselects the data for word 1
of data set 2. Parameter
displays the selected data in integer format. If no data is
preselected, the value to be sent can be written directly into
parameter 61.95.
None.
Control Word (16 bits)
Status Word (16 bits)
Actual value ACT1 (16 bits)
Actual value ACT2 (16 bits)
on page
value.
61.01 M/F data 1
value.
61.01 M/F data 1
61.01 M/F data 1
61.02 M/F data 2
61.03 M/F data 3
preselect data to be sent in data
=
ABB standard
display the data to be sent to the
61.95 Data set 2 data 1 value
Def/FbEq16
28
-
Used speed
reference
Torque
reference act
5
0
0
0
None
drive).
0
1
4
5
6