Winder Speed Settings - ABB ACS880 Firmware Manual

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
74
75 Winder speed
settings
75.01
Max line speed
0.0...
32767.0 m/min
75.02
Line speed
reference src
NULL
AI1_SCALED
AI2_SCALED
FBA Reference 1
FBA Reference 2
M/F or D2D
Reference 1
M/F or D2D
Reference 2
Motor
Potentiometer Ref
Other
75.03
Line reference
scaling
0.00...32767.00
Description
Ramping time adjustments and winder-related speed
reference adaptation setup.
See section
Line speed
Defines the maximum linear speed the production line is
intended to run at.
Maximum speed of the machinery.
Selects the source for the line speed reference. The target
line speed reference is defined as:
75.51 Line reference In
75.03 Line reference
scaling) *
Zero.
12.12 AI1 scaled value
(see page 197).
12.22 AI2 scaled value
(see page 198).
03.05 FB A reference 1
03.06 FB A reference 2
03.13 M/F or D2D ref1
(see page 160).
03.14 M/F or D2D ref2
(see page 161).
Motor potentiometer reference. See parameter
potentiometer ref act
on page 256.
Source selection (see
Terms and abbreviations
152).
Defines the custom scaling factor for line speed reference.
For example, if line speed reference from the fieldbus is
scaled from 0 to ± 20000 (INT), then set this value to 200.00
(REAL).
Note: Reference scaling can be set to 0, then input from
parameter
75.02
is interpreted directly as m/min (or ft/min)
without any scaling.
Scaling factor.
on page 48.
=
(75.02 Line speed reference
75.01 Max line speed
(see page 160).
(see page 160).
22.80 Motor
Parameters 419
Def/FbEq16
700.0 m/min
10 = 1 m/min
AI1_SCALE
D
src/
0
1
2
3
4
5
6
7
on page
-
200.00
100 = 1