ABB ACS880 Firmware Manual page 391

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
58.28
EFB act1 type
Auto
Transparent
General
Torque
Speed
Frequency
Position
58.29
EFB act2 type
Auto
Transparent
General
Torque
Speed
Frequency
Position
58.30
EFB status word
transparent source
Not selected
Other
58.31
EFB act1
transparent source
Not selected
Other
Description
Selects the type/source and scaling of actual value 1
transmitted to the fieldbus network through the embedded
fieldbus interface.
Type/source and scaling follow the type of reference 1
selected by parameter
58.26 EFB ref1
individual settings below for the sources and scalings.
The value selected by parameter
transparent source
is sent as actual value 1. No scaling is
applied (the 16-bit scaling is 1 = 1 unit).
The value selected by parameter
transparent source
is sent as actual value 1 with a 16-bit
scaling of 100 = 1 unit (i.e. integer and two decimals).
01.10 Motor torque
is sent as actual value 1. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
scaling is defined by parameter
01.06 Output frequency
scaling is defined by parameter
Motor position is sent as actual value 1. See parameter
90.06 Motor position
scaled.
Selects the type/source and scaling of actual value 2
transmitted to the fieldbus network through the embedded
fieldbus interface.
Type/source and scaling follow the type of reference 1
selected by parameter
58.27 EFB ref2
individual settings below for the sources and scalings.
The value selected by parameter
transparent source
is sent as actual value 2. No scaling is
applied (the 16-bit scaling is 1 = 1 unit).
The value selected by parameter
transparent source
is sent as actual value 2 with a 16-bit
scaling of 100 = 1 unit (i.e. integer and two decimals).
01.10 Motor torque
is sent as actual value 2. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
scaling is defined by parameter
01.06 Output frequency
scaling is defined by parameter
Motor position is sent as actual value 2. See parameter
90.06 Motor position
scaled.
Selects the source of the status word when
profile
is set to Transparent.
None.
Source selection (see
Terms and abbreviations
page 152).
Selects the source of actual value 1 when
type
is set to
Transparent
None.
Source selection (see
Terms and abbreviations
page 152).
type. See the
58.31 EFB act1
58.31 EFB act1
scaling.
is sent as actual value 1. The
46.01 Speed
scaling.
is sent as actual value 1. The
46.02 Frequency
type. See the
58.32 EFB act2
58.32 EFB act2
scaling.
is sent as actual value 2. The
46.01 Speed
scaling.
is sent as actual value 2. The
46.02 Frequency
58.25 Control
on
58.28 EFB act1
or General.
on
Parameters 391
Def/FbEq16
Auto
0
1
2
3
4
5
scaling.
6
Torque
0
1
2
3
4
5
scaling.
6
Not selected
0
-
Not selected
0
-