ABB ACS880 Firmware Manual page 299

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
30.19
Minimum torque 1
-1600.0 ... 0.0%
30.20
Maximum torque 1
0.0 ... 1600.0%
30.21
Minimum torque 2
source
Zero
AI1 scaled
AI2 scaled
PID
Minimum torque 2
Other
30.22
Maximum torque 2
source
Zero
AI1 scaled
AI2 scaled
PID
Maximum torque 2
Description
Defines a minimum torque limit for the drive (in percent of
nominal motor torque). See diagram at parameter
Minimum torque
sel.
The limit is effective when
• the source selected by
30.18
is set to
Minimum torque
Note: Do not set this parameter to 0% in an attempt to
prevent reverse rotation. In an open-loop application, that is
likely to prevent the motor from stopping altogether. To
prevent reverse rotation, use the speed/frequency limits in
this parameter group, or parameters 20.23/20.24.
Minimum torque limit 1.
Defines a maximum torque limit for the drive (in percent of
nominal motor torque). See diagram at parameter
Minimum torque
sel.
The limit is effective when
• the source selected by
30.25
is set to
Maximum torque
Maximum torque 1.
Defines the source of the minimum torque limit for the drive
(in percent of nominal motor torque) when
• the source selected by parameter
sel
is 1, or
30.18
is set to
Minimum torque 2
See diagram at
30.18 Minimum torque
Note: Any positive values received from the selected source
are inverted.
None.
12.12 AI1 scaled value
(see page 197).
12.22 AI2 scaled value
(see page 198).
40.01 Process PID output actual
controller).
30.23 Minimum torque
2.
Source selection (see
Terms and abbreviations
152).
Defines the source of the maximum torque limit for the drive
(in percent of nominal motor torque) when
• the source selected by parameter
sel
is 1, or
30.25
is set to
Maximum torque 2
See diagram at
30.18 Minimum torque
Note: Any negative values received from the selected
source are inverted.
None.
12.12 AI1 scaled value
(see page 197).
12.22 AI2 scaled value
(see page 198).
40.01 Process PID output actual
controller).
30.24 Maximum torque
30.18 Minimum torque sel
1.
30.25 Maximum torque sel
1.
30.18 Minimum torque
source.
sel.
(output of the process PID
30.25 Maximum torque
source.
sel.
(output of the process PID
2.
Parameters 299
Def/FbEq16
-300.0%
30.18
is 0, or
See par.
46.03
300.0%
30.18
is 0, or
See par.
46.03
Minimum
torque 2
0
1
2
5
6
on page
-
Maximum
torque 2
0
1
2
5
6