Process Pid Set 2 - ABB ACS880 Firmware Manual

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

354 Parameters
No.
Name/Value
DI3
DI4
DI5
DI6
DIO1
DIO2
Other [bit]
40.91
Feedback data
storage
-327.68 ... 327.67
40.92
Setpoint data
storage
-327.68 ... 327.67
41

41 Process PID set 2

41.07
Set 2 PID operation
mode
41.08
Set 2 feedback 1
source
41.09
Set 2 feedback 2
source
41.10
Set 2 feedback
function
41.11
Set 1 feedback filter
time
41.12
Set 1 unit selection
rpm
%
Hz
PID user unit 2
41.14
Set 1 setpoint
scaling
Description
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Digital input/output DIO1
Digital input/output DIO2
Source selection (see
Terms and abbreviations
page 152).
Storage parameter for receiving a process feedback value
e.g. through the embedded fieldbus interface.
The value can be sent to the drive as Modbus I/O data. Set
the target selection parameter of that particular data
(58.101...58.124) to
Feedback data
feedback 1 source
(or
40.09 Set 1 feedback 2
select
Feedback data
storage.
Storage parameter for process feedback.
Storage parameter for receiving a process setpoint value
e.g. through the embedded fieldbus interface.
The value can be sent to the drive as Modbus I/O data. Set
the target selection parameter of that particular data
(58.101...58.124) to
Setpoint data
setpoint 1 source
(or
40.17 Set 1 setpoint 2
Setpoint data
storage.
Storage parameter for process setpoint.
A second set of parameter values for process PID control.
The selection between this set and first set (parameter
group
40 Process PID set
PID set1/set2
selection.
See also parameters 40.01...40.06, 40.91, 40.92and the
control chain diagrams on pages
See parameter
40.07 Set 1 PID operation
See parameter
40.08 Set 1 feedback 1
See parameter
40.09 Set 1 feedback 2
See parameter
40.10 Set 1 feedback
See parameter
40.11 Set 1 feedback filter
Defines the unit for parameter
rpm.
%.
Hz.
User-definable unit 2. The name of the unit can be edited on
the control panel by choosing Menu − Settings − Edit texts.
See parameter
40.14 Set 1 setpoint
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on
storage. In
40.08 Set 1
source),
storage. In
40.16 Set 1
source), select
1) is made by parameter
658
and 659.
mode.
source.
source.
function.
time.
41.21...41.24
and 41.27.
scaling.
Def/FbEq16
5
6
7
8
11
12
-
-
100 = 1
-
100 = 1
40.57
Off
AI1 scaled
Not selected
In1
0.000 s
%
7
4
3
249
100.00