ABB ACS880 Firmware Manual page 68

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

68 Standard program features
Inputs available to the adaptive program
Input
Enabled
Inhibited
Ready to start
Tripped
At setpoint
Limiting
Ext1 active
Ext2 active
Data storage
Data storage 1 real32
Data storage 2 real32
Data storage 3 real32
Data storage 4 real32
Data storage 5 real32
Data storage 6 real32
Data storage 7 real32
Data storage 8 real32
Outputs available to the adaptive program
Output
I/O
RO1
RO2
RO3
AO1
AO2
DIO1
DIO2
Start control
Ext1/Ext2 selection
Run enable 1
Ext1 in1 cmd
Ext1 in2 cmd
Ext1 in3 cmd
Ext2 in1 cmd
Ext2 in2 cmd
Ext2 in3 cmd
Fault reset
Speed control
Speed ref1
Source
06.16 Drive status word
06.16 Drive status word
06.16 Drive status word
06.11 Main status
word, bit 3
06.11 Main status
word, bit 8
06.16 Drive status word
06.16 Drive status word
06.16 Drive status word
47.01 Data storage 1 real32
47.02 Data storage 2 real32
47.03 Data storage 3 real32
47.04 Data storage 4 real32
47.05 Data storage 5 real32
47.06 Data storage 6 real32
47.07 Data storage 7 real32
47.08 Data storage 8 real32
Target
10.24 RO1 source
10.27 RO2 source
10.30 RO3 source
13.12 AO1 source
13.22 AO2 source
11.06 DIO1 output source
11.10 DIO2 output source
19.11 Ext1/Ext2 selection
20.12 Run enable 1 source
20.03 Ext1 in1 source
20.04 Ext1 in2 source
20.05 Ext1 in3 source
20.08 Ext2 in1 source
20.09 Ext2 in2 source
20.10 Ext2 in3 source
31.11 Fault reset selection
22.11 Speed ref1 source
1, bit 0
1, bit 1
1, bit 3
1, bit 7
1, bit 10
1, bit 11