ABB ACS880 Firmware Manual page 303

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
31.11
Fault reset selection
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
FBA A MCW bit 7
EFB MCW bit 7
Other [bit]
Description
Selects the source of an external fault reset signal. The
signal resets the drive after a fault trip if the cause of the
fault no longer exists.
0 - > 1 = Reset
Note: A fault reset from the fieldbus interface is always
observed regardless of this parameter.
0.
1.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Digital input/output DIO1
Digital input/output DIO2
Control word bit 7 received through fieldbus interface A.
Control word bit 7 received through the embedded fieldbus
interface.
Source selection (see
Terms and abbreviations
page 152).
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on
Parameters 303
Def/FbEq16
DI3
0
1
2
3
4
5
6
7
10
11
30
32
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents