ABB ACS880 Firmware Manual page 398

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

398 Parameters
No.
Name/Value
Warning
Fault
60.18
Follower enable
MSW bit 0
MSW bit 1
MSW bits 0 + 1
Always
MSW bit 12
MSW bits 0 + 12
MSW bits 1 + 12
60.19
M/F comm
supervision sel 1
Bit
Name
0
Follower 1
1
Follower 2
...
...
15
Follower 16
0000h...FFFFh
Description
The drive generates a warning
Drive trips on
FF7E
Follower. All followers will be stopped.
Interlocks the starting of the master to the status of the
followers.
Note: Each follower must be configured to transmit its status
word as one of the three data words in parameters
61.01...61.03. In the master, the corresponding target
parameter (62.04...62.12) must be set to
The master can only be started if all followers are ready to
switch on (bit 0 of
06.11 Main status word
on).
The master can only be started if all followers are ready to
operate (bit 1 of
06.11 Main status word
on).
The master can only be started if all followers are ready to
switch on and ready to operate (bits 0 and 1 of
status word
in each follower are on).
The starting of the master is not interlocked to the status of
the followers.
The master can only be started if user-definable bit 12 of
06.11 Main status word
parameter
06.31 MSW bit 12
The master can only be started if both bit 0 and bit 12 of
06.11 Main status word
The master can only be started if both bit 1 and bit 12 of
06.11 Main status word
(This parameter is only effective when the drive is the
master on a drive-to-drive master/follower link. See
parameters
60.01 M/F communication port
mode.)
In the master, parameters
1
and
60.20 M/F comm supervision sel 2
followers that are monitored for loss of communication.
This parameter selects which followers (out of followers
1...16) are monitored. Each of the selected followers is
polled by the master. If no reply is received, the action
specified in
60.09 M/F comm loss function
The status of communication is shown by
communication status 1
status
2.
Description
1 = Follower 1 is polled by the master.
1 = Follower 2 is polled by the master.
...
1 = Follower 16 is polled by the master.
Selection of followers for communication supervision (1).
(AFE7
Follower).
Follower
in each follower is
in each follower is
06.11 Main
in each follower is on. See
sel.
in each follower is on.
in each follower is on.
and
60.19 M/F comm supervision sel
specify the
is taken.
62.37 M/F
and
62.38 M/F communication
Def/FbEq16
1
2
Always
SW.
0
1
2
3
4
5
6
-
60.03 M/F
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading