No.
Name/Value
62.42
M/F follower ready
status 2
Bit
Name
0
Follower 17
1
Follower 18
...
...
15
Follower 32
0000h...FFFFh
62.45
Data set 1 data 1
selection
None
CW 16bit
Ref1 16bit
Ref2 16bit
Other
62.46
Data set 1 data 2
selection
62.47
Data set 1 data 3
selection
...
...
62.50
Data set 3 data 3
selection
62.51
Data set 10 data 1
selection
None
CW 16bit
Description
In the master, displays the ready status of the
communication with followers specified by parameter
M/F status supervision sel
Description
1 = Follower 17 ready.
1 = Follower 18 ready.
...
1 = Follower 32 ready.
Follower 17...32 ready status.
Parameters
62.45...62.50
received in data sets 1 and 3 from the external controller.
These data sets are used in ModuleBus communication with
a "standard drive"
(60.50 DDCS controller drive type
standard
drive).
Parameters
62.95...62.100
the external controller in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of
data set 1. Parameter
62.95 Data set 1 data 1 value
the received data in integer format, and can also be used as
a source by other parameters.
None.
Control Word (16 bits)
Reference REF1 (16 bits)
Reference REF2 (16 bits)
Source selection (see
Terms and abbreviations
152).
Defines a target for the data received as word 2 of data set
1.
See also parameter
62.96 Data set 1 data 2
For the selections, see parameter
selection.
See parameter
62.45 Data set 1 data 1
...
See parameter
62.45 Data set 1 data 1
Parameters
62.51...62.74
received in data sets 10, 12, 14, 16, 18, 20, 22 and 24 from
the external controller.
Parameters
62.101...62.124
the external controller in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of
data set 10. Parameter
62.101 Data set 10 data 1 value
displays the received data in integer format, and can also be
used as a source by other parameters.
None.
Control Word (16 bits)
2.
define a target for the data
display the data received from
on page
value.
62.45 Data set 1 data 1
selection.
selection.
define a target for the data
display the data received from
Parameters 413
Def/FbEq16
-
60.24
1 = 1
None
=
ABB
displays
0
1
2
3
-
None
None
...
None
None
0
1