ABB ACS880 Firmware Manual page 171

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
06.18
Start inhibit status
word
Bit Name
0
Not ready run
1
Ctrl location
changed
2
SSW inhibit
3
Fault reset
4
Lost start enable
5
Lost run enable
6
FSO inhibit
7
STO
8
Current calibration
ended
9
ID run ended
10 Auto phase ended
11 Em Off1
12 Em Off2
13 Em Off3
14 Auto reset inhibit
15 Jogging active
Notes:
a
If bit 1 of
and edge triggering is selected for the active external control location, a fresh rising-edge
start signal is required. See parameters 20.02,
b
If bit 1 of
fresh rising-edge start signal is required.
c
Informative bit. The inhibiting condition need not be removed by the user.
0000h...FFFFh
Description
Start inhibit status word. This word specifies the source of
the inhibiting condition that prevents the drive from starting.
After the condition is removed, the start command must be
cycled. See bit-specific notes.
See also parameter
06.16 Drive status word
This parameter is read-only.
Description
1 = DC voltage is missing or drive has not been parametrized
correctly. Check the parameters in groups
1 = Control location has changed
1 = Control program is keeping itself in inhibited state
1 = A fault has been reset
1 = Start enable signal missing
1 = Run enable signal missing
1 = Operation prevented by FSO-xx safety functions module
1 = Safe torque off is active
1 = Current calibration routine has finished
1 = Motor identification run has finished
1 = Autophasing routine has finished
1 = Emergency stop signal (mode off1)
1 = Emergency stop signal (mode off2)
1 = Emergency stop signal (mode off3)
1 = The autoreset function is inhibiting operation
1 = The jogging enable signal is inhibiting operation
06.16 Drive status word 1
06.16 Drive status word 1
Start inhibit status word.
06.25 Drive inhibit status word
1, bit 1.
is still set after the removal of the inhibiting condition,
20.07
and 20.19.
is still set after the removal of the inhibiting condition, a
Parameters 171
Def/FbEq16
-
2, and
Note
a
95
and 99.
a,c
a
a,c
a
a
b
b
b,c
b,c
b,c
b
b
b
b
1 = 1