ABB ACS880 Firmware Manual page 366

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

366 Parameters
No.
Name/Value
46.04
Power scaling
0.10 ... 30000.00
kW or
0.10 ... 40214.48
hp
46.05
Current scaling
0...30000 A
46.06
Speed ref zero
scaling
0.00 ...
30000.00 rpm
46.07
Frequency ref zero
scaling
0.00 ... 1000.00 Hz
46.11
Filter time motor
speed
2...20000 ms
46.12
Filter time output
frequency
2...20000 ms
46.13
Filter time motor
torque
2...20000 ms
46.14
Filter time power out
2...20000 ms
Description
Defines the output power value that corresponds to 10000 in
fieldbus, master/follower etc. communication. The unit is
selected by parameter
96.16 Unit
Power corresponding to 10000 on fieldbus.
Defines the 16-bit scaling of current parameters. The value
of this parameter corresponds to 10000 in fieldbus,
master/follower etc. communication.
Current corresponding to 10000 on fieldbus.
Defines a speed corresponding to a zero reference received
from fieldbus (either the embedded fieldbus interface, or
interface FBA A or FBA B). For example, with a setting of
500, the fieldbus reference range of 0...20000 would
correspond to a speed of 500...[46.01] rpm.
Note: This parameter is effective only with the ABB Drives
communication profile.
Speed corresponding to minimum fieldbus reference.
Defines a frequency corresponding to a zero reference
received from fieldbus (either the embedded fieldbus
interface, or interface FBA A or FBA B). For example, with a
setting of 30, the fieldbus reference range of 0...20000
would correspond to a speed of 30...[46.02] Hz.
Note: This parameter is effective only with the ABB Drives
communication profile.
Frequency corresponding to minimum fieldbus reference.
Defines a filter time for signals
01.02 Motor speed
estimated,
filtered
and
01.05 Encoder 2 speed
Motor speed signal filter time.
Defines a filter time for signal
Output frequency signal filter time.
Defines a filter time for signal
Motor torque signal filter time.
Defines a filter time for signal
Output power signal filter time.
selection.
01.01 Motor speed
used,
01.04 Encoder 1 speed
filtered.
01.06 Output
frequency.
01.10 Motor
torque.
01.14 Output
power.
Def/FbEq16
1000.00 kW
or hp
1 = 1 unit
10000 A
1 = 1 A
0.00 rpm
1 = 1 rpm
0.00 Hz
10 = 1 Hz
500 ms
1 = 1 ms
500 ms
1 = 1 ms
100 ms
1 = 1 ms
100 ms
1 = 1 ms

Hide quick links: