No.
Name/Value
96.05
Macro active
Factory
Hand/Auto
PID-CTRL
T-CTRL
Sequence control
FIELDBUS
96.06
Parameter restore
Done
Restore defaults
Clear all
Reset all fieldbus
settings
96.07
Parameter save
manually
Done
Save
Description
Shows which application macro is currently selected. See
chapter
Application macros
To change the macro, use parameter
Factory macro (see page 136).
Hand/Auto macro (see page 138).
PID control macro (see page 140).
Torque control macro (see page 144).
Sequential control macro (see page 146).
Fieldbus control macro (see page 149).
Restores the original settings of the control program, i.e.
parameter default values.
Note: This parameter cannot be changed while the drive is
running.
Restoring is completed.
All editable parameter values are restored to default values,
except
• motor data and ID run results
• parameter
31.42 Overcurrent fault limit
• control panel/PC communication settings
• I/O extension module settings
• fieldbus adapter settings
• encoder configuration data
• application macro selection and the parameter defaults
implemented by it
• parameter
95.01 Supply voltage
• differentiated defaults implemented by parameters
HW options word 1
and
• user lock configuration parameters
All editable parameter values are restored to default values,
except
• control panel/PC communication settings
• application macro selection and the parameter defaults
implemented by it
• parameter
95.01 Supply voltage
• differentiated defaults implemented by parameters
HW options word 1
and
• user lock configuration parameters 96.100...96.102.
PC tool communication is interrupted during the restoring.
Fieldbus adapter and embedded fieldbus interface settings
(parameter groups 50...58) are restored to default values.
This will also restore the default settings of the fieldbus
adapter if one is connected.
Saves the valid parameter values to permanent memory.
This parameter should be used to store values sent from a
fieldbus, or when using an external power supply to the
control board as the supply might have a very short hold-up
time when powered off.
Note: A new parameter value is saved automatically when
changed from the PC tool or control panel but not when
altered through a fieldbus adapter connection.
Save completed.
Save in progress.
(page 135) for more information.
96.04 Macro
95.21 HW options word 2
96.100...96.102
95.21 HW options word 2
Parameters 483
Def/FbEq16
Factory
select.
1
2
3
4
5
6
Done
0
8
95.20
62
95.20
32
Done
0
1