No.
Name/Value
13.28
AO2 source max
-32768.0 ...
32767.0
13.29
AO2 out at AO2 src
min
0.000 ... 22.000 mA Minimum AO2 output value.
13.30
AO2 out at AO2 src
max
0.000 ... 22.000 mA Maximum AO2 output value.
13.91
AO1 data storage
-327.68 ... 327.67
13.92
AO2 data storage
-327.68 ... 327.67
14
14 I/O extension module
1
14.01
Module 1 type
None
FIO-01
FIO-11
FDIO-01
FAIO-01
14.02
Module 1 location
Slot 1
Slot 2
Slot 3
4...254
Description
Defines the real maximum value of the signal (selected by
parameter
13.22 AO2
source) that corresponds to the
maximum required AO2 output value (defined by
parameter
13.30 AO2 out at AO2 src
13.27 AO2 source
min.
Real signal value corresponding to maximum AO2 output
value.
Defines the minimum output value for analog output AO2.
See also drawing at parameter
Defines the maximum output value for analog output AO2.
See also drawing at parameter
Storage parameter for controlling analog output AO1 e.g.
through fieldbus.
In
13.12 AO1
source, select
parameter as the target of the incoming value data.
With the embedded fieldbus interface, simply set the target
selection parameter of that particular data (58.101...58.124)
to
AO1 data
storage.
Storage parameter for AO1.
Storage parameter for controlling analog output AO2 e.g.
through fieldbus.
In
13.22 AO2
source, select
parameter as the target of the incoming value data.
With the embedded fieldbus interface, simply set the target
selection parameter of that particular data (58.101...58.124)
to
AO2 data
storage.
Storage parameter for AO2.
Configuration of I/O extension module 1.
See also section
Programmable I/O extensions
Note: The contents of the parameter group vary according
to the selected I/O extension module type.
Activates (and specifies the type of) I/O extension module 1.
Inactive.
FIO-01.
FIO-11.
FDIO-01.
FAIO-01.
Specifies slots (1...3) on the control unit of the drive into
which the I/O extension module is installed. Also specifies
the node ID of the slot on the FEA-03 extension adapter.
Slot 1.
Slot 2.
Slot 3.
Node ID of the slot on the FEA-03 extension adapter.
max). See parameter
13.27 AO2 source
min.
13.27 AO2 source
min.
AO1 data
storage. Then set this
AO2 data
storage. Then set this
(page 72).
Parameters 203
Def/FbEq16
100.0
1 = 1
0.000 mA
1000 = 1 mA
20.000 mA
1000 = 1 mA
0.00
100 = 1
0.00
100 = 1
None
0
1
2
3
4
Slot 1
1
2
3
1 = 1