ABB ACS880 Firmware Manual page 581

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

Code
Warning
(hex)
A7EE
Control panel loss
Programmable warning:
49.05 Communication loss
action
A880
Motor bearing
Programmable warnings:
33.14 On-time 1 warn
message
33.24 On-time 2 warn
message
33.55 Value counter 1
warn message
33.65 Value counter 2
warn message
A881
Output relay
A882
Motor starts
A883
Power ups
A884
Main contactor
A885
DC charge
A886
On-time 1
(Editable message text)
Programmable warning:
33.14 On-time 1 warn
message
A887
On-time 2
(Editable message text)
Programmable warning:
33.24 On-time 2 warn
message
A888
Edge counter 1
(Editable message text)
Programmable warning:
33.35 Edge counter 1
warn message
Cause
0009 Absolute encoder initialization
error
000A Absolute SSI encoder
configuration error
000B Encoder reported an internal
error
000C Encoder reported a battery
error
000D Encoder reported overspeed
or decreased resolution due to
overspeed
000E Encoder reported a position
counter error
000F Encoder reported an internal
error
Control panel or PC tool has
stopped communicating.
Warning generated by an on-
time timer or a value counter.
Warning generated by an edge
counter.
Programmable warnings:
33.35 Edge counter 1 warn
message
33.45 Edge counter 2 warn
message
Warning generated by on-time
timer 1.
Warning generated by on-time
timer 2.
Warning generated by edge
counter 1.
Fault tracing 581
What to do
Contact your local ABB representative.
Contact your local ABB representative.
See the documentation of the encoder.
See the documentation of the encoder.
See the documentation of the encoder.
See the documentation of the encoder.
See the documentation of the encoder.
Check PC tool or control panel
connection.
Check control panel connector.
Check mounting platform if being used.
Disconnect and reconnect the control
panel.
Check the event log for an auxiliary code.
Check the source of the warning
corresponding to the code:
0:
33.13 On-time 1 source
1:
33.23 On-time 2 source
4:
33.53 Value counter 1 source
5:
33.63 Value counter 2
Check the event log for an auxiliary code.
Check the source of the warning
corresponding to the code:
2:
33.33 Edge counter 1 source
3:
33.43 Edge counter 2
Check the source of the warning
(parameter
33.13 On-time 1
Check the source of the warning
(parameter
33.23 On-time 2
Check the source of the warning
(parameter
33.33 Edge counter 1
source).
source.
source.
source).
source).

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents