ABB ACS880 Firmware Manual page 418

Industrial drives, winder control program, option +n5000
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

418 Parameters
No.
Name/Value
74.51
Winder control
status
Bit
Name
0
Winding mode unwinder
1
Winding direction is negative
2
Open loop Tctrl forced
3
Reserved
4
Diameter Reset command
5
Diameter Preset command
6
Count up enabled
7
Count down enabled
8
Torq memory sample
9
Torq memory enabled
10
Tension control enabled
11
Stall function enabled
12
Inertia compensation enabled
13
Friction compensation enabled 1 = Friction compensation is enabled
14
Threading forward command
15
Threading reverse command
0x0000... 0xffff
74.61
Used length
0.0... 100000.0 m
74.91
Unit system
Metric
Imperial
Description
Status word showing active control settings of the
application.
This parameter is read-only.
Val.
1 = Command to unwind
0 = Command to wind
1 = Winding direction negative
0 = Winding direction positive
1 = Force open loop control
0 = Normal operation
1 = Reset diameter
0 = Normal operation
1 = Preset diameter
0 = Normal operation
1 = Count up is enabled
0 = Count up is disabled
1 = Count down is enabled
0 = Count down is disabled
1 = Torque memory sampling is enabled
0 = Normal operation
1 = Torque memory is enabled
0 = Normal operation
1 = Regulator control is enabled
0 = Normal operation (pure speed control)
1 = Stall mode is enabled
0 = Stall mode is disabled
1 = Inertia compensation is enabled
0 = Normal operation
0 = Normal operation
1 = Command to threading forward
0 = Normal operation
1 = Command to threading reverse
0 = Normal operation
Winder control status.
Displays the material length used in software internal
calculations.
This parameter is read-only.
Material length used.
Selects the used unit system.
Uses the Metric unit system.
Uses the Imperial unit system.
Description
Def/FbEq16
0x0000
1 = 1
0.0 m
10 = 1 m
Metric
0
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents