No.
Name/Value
49.07
Panel comm
supervision force
Bit
Name
0
Ext 1
1
Ext 2
2
Local
3...15
Reserved
0000b...0111b
49.08
Secondary comm.
loss action
No action
Warning
49.14
Panel speed
reference unit
rpm
%
49.15
Minimum ext speed
ref panel
-30000.00 ...
30000.00 rpm
49.16
Maximum ext speed
ref panel
-30000.00 ...
30000.00 rpm
49.17
Minimum ext
frequency ref panel
-500.00 ...
500.00 Hz
Description
Activates control panel communication monitoring
separately for each control location (see section
control vs. external control
The parameter is primarily intended for monitoring the
communication with the panel when it is connected to the
application program and not selected as a control source by
drive parameters.
Value
1 = Communication monitoring active when Ext 1 is being used.
1 = Communication monitoring active when Ext 2 is being used.
1 = Communication monitoring active when local control is being
used.
Panel communication monitoring selection.
Selects how the drive reacts to a control panel (or PC tool)
communication break when the panel is parametrized as an
alternative control or reference source but is not currently
the active source.
No action taken.
Drive generates an
A7EE Control panel loss
WARNING! Make sure that it is safe to continue
operation in case of a communication break.
Defines the unit for speed reference when given from the
control panel.
rpm.
Percent of parameter
46.01 Speed
Defines a minimum limit for control panel speed reference in
external control.
In local control, the limits in parameter group
force. See section
Local control vs. external control
(page 40).
Minimum speed reference.
Defines a maximum limit for control panel speed reference
in external control.
In local control, the limits in parameter group
force. See section
Local control vs. external control
(page 40).
Maximum speed reference.
Defines a minimum limit for control panel frequency
reference in external control.
In local control, the limits in parameter group
force. See section
Local control vs. external control
(page 40).
Minimum frequency reference.
Local
on page 40).
warning.
scaling.
30 Limits
30 Limits
30 Limits
Parameters 373
Def/FbEq16
0000b
1 = 1
No action
0
5
rpm
0
1
-30000.00
rpm
are in
See par.
46.01
30000.00
rpm
are in
See par.
46.01
-500.00 Hz
are in
See par.
46.02